Specifications
Dimensions | Height (Top) = 49.4mm (height above tank mount – not including horn section 50mm). Diameter (115mm). |
Weight | 10oz (280g) |
Housing Material | UV Stabilized PVDF [Kynar] and PP material |
Operating Temperature 1 | +13°F to +122°F (-25°C to +50°C) |
Storage Temperature 1 | +32°F to +86°F (+0°C to +30°C) |
Humidity Range | 10% to 100% |
Altitude Range | <6500 feet (<2Km) above sea level |
Environmental Protection | IP68 – Outdoors |
Battery | Lithium LiSOCl2 replaceable |
Battery Life 3 | Up to 10 years |
Radar Range 2 | >3.2 inches to <22 feet (>10cm to <6.75m) |
Radar Resolution | Up to 2mm |
Radar Accuracy | Nominal +/-4mm @ 2m range |
Material Compatibility | Suitable for use in tanks for the storage of water diesel fuel, kerosene, gas oil types A2, C1, C2 and D as defined by BS2869. Consult Veeder-Root for other applications. |
Communications | Cat M1/Cat NB1: LTE FDD: B1/B2/B3/B4/B5/B8/B12/B13/B18/B19/B20/B26/B28 LTE TDD: B39 (For Cat M1 Only). EGPRS: 850/900/1800/1900MH 2G fall-back. Bluetooth Low Energy (BLE) V4.3 for installation and customer local readings. |
ATEX Approval | IECEx II (1)G Ex ia IIB T4 [-25 < Ta < +50°C] [-13 < Ta < +122°F] and North American Class 1, Division 1 UL 913. |
Gasket (included) | Viton seal included |
Adaptor | 2” adapter, optional non-invasive adapter with adhesive pad. |
1 Storage and operation above +68°F (+20°C) may reduce battery life. Minimum distance measured is derated with temperatures <32°F (<0°C).
2 Based on a measurement to a flat liquid target of size 4.65in2 (30cm2) and γ reflectivity of liquid or object. E.g.: Kerosene range is typically 4m due to lower dielectric constant. Consult Veeder-Root for range limits for various media. Non-invasive range is dependent on tank and liquid type – consult factory for further details.
3 One communication per day and assumes a good signal strength, so that no retries are required. One sample every 60 minutes.