Veeder-Root's TLS-350R Monitoring System adds value to automatic tank gauging with a highly advanced, automatic inventory management capability - Business Inventory Reconciliation. This fully integrated system automatically collects dispensing data, in-tank inventories and deliveries, and reconciles the totals at the end of each shift, day or period into a comprehensive reconciliation report to meet federal, state, and local requirements. It also interfaces directly with electronic or mechanical dispensers to automatically access metered sales information. The TLS-350R is available with CSLD for 24-hour leak detection without tank shut down.
The TLS-350R uses AccuChart, Veeder-Root's patented tank calibration algorithm, to minimize errors due to dynamics, such as tank tilt, deflection and end shape, to create an optimal tank chart for each tank in the system. The automatic calibration process, which typically takes one month, is conducted through the typical operating levels in the tank as fuel is dispensed. Once enough valid data has been analyzed, the tank calibration is complete. An updated tank chart can be retrieved from the TLS-350R through an RS-232 interface using a computer.
Automatic Tank-To-Meter Mapping, which typically takes up to 2 days, eliminates the possibility that product being dispensed through the meter is reconciled against the wrong product. When dispensing begins, the TLS-350R recognizes a reduction in in-tank inventory and is alerted through a Dispenser Interface Module (DIM) that a specific meter is running. When the metered volume data equals an inventory reduction, the mapping feature matches that meter and tank.
The TLS-350R is available with an integral printer or can be interfaced with a remote printer. The system can be programmed to generate reports at the end of a shift, day, or period. Periodic reports are programmable to cover up to a 35-day cycle and can print in either column (summary) or row (line item) formats.
An adjusted delivery report makes sure you get what you pay for. When a bulk delivery is made, the TLS-350R measures the amount of any fuel dispensed during the delivery and the system provides a report showing the volume increase, the amount of fuel dispensed during the delivery, and the actual delivery amount.
The TLS-350R automatically calculates periodic variance thresholds based on the U.S. E.P.A. requirement of +/- (1% of monthly throughput +130 gallons) and includes them on the Periodic Reconciliation Report. The variance threshold is programmable so it can be set to local regulations if necessary.
Features
- Automatic Business Inventory Reconciliation
- AccuChartTM Automatic Tank Calibration
- Automatic Tank-To-Meter Mapping
- 0.1 GPH and 0.2 GPH In-Tank Leak Detection with Magnetostrictive Probes
- Electronic Line Leak Detection Capabilities
- Inventory Monitoring and Reporting
- Interstitial/Sump Leak Sensing Capabilities
- Vapor Well Monitoring Capability
- Groundwater Monitoring Capability
- Input/Output Capability
- Sump and Dispenser Monitoring Capabiliteis
- RS-232 Data Communications
- Internal Modem
- Auto-Dial Fax (SiteFax)
- Optional Integral Printer or Remote Printer Interface
- Emergency generator applications selectable via programming
- One system handles mix of standard and emergency generator tanks
- Records generator activity
- Complete inventory reports before and after generator operation
- Audible and Visual Alarm Capabilities
- Monitors up to 12 tanks
- Maximum Tank Capacity: 15,000 Gallons; 37,000 gallons with CSLD software enhancement
- Leak Testing and Reconciliation for Manifolded Tanks
Standard Models
Console Form Number: 848290-102
Description: TLS-350R Console without Integral Printer
Console Form Number: 848290-122
Description: TLS-350R Console with Integral Printer
Console Form Number: 330532-001
Description: Memory Expansion Module (required to support BIR for manifolded tanks only)
TLS-350R Interface ModulesThe TLS-350R monitoring console contains three compartments in which individual interface modules can be installed. Interface modules may be factory-installed in the console upon initial ordering, or ordered separately as spare modules to expand an existing system.
Low-Power Compartment (Limit eight per console, unless otherwise noted.)
| Form No. Factory Installed Modules |
Description |
Feature Compatibility |
| 329356-002 |
Four-Input Probe Interface Module (Maximum three per console. Includes terminal connector for one ground temperature thermistor for the volumetric line leak detector). |
Series 8463 Mag Plus Probe |
| 329358-001 |
Eight-Input Interstitial/Liquid Sensor |
Series 7943 Interstitial Sensor for Fiberglass Tanks and Interstitial Sensor for Steel Tanks Series 7943 Piping Sump Sensor Series 7943 Hydrostatic Sensor |
| 329357-001 |
Five-Input Vapor Sensor Interface Module |
Series 7943 Vapor Sensor |
| 329399-001 |
Five-Input Groundwater Sensor Module |
4SITE Series 7943 Groundwater Sensor |
| 329956-001 |
Eight-Input Type A Sensor Interface Module |
4SITE Series 7943 Solid State Discriminating Interstitial Sensor |
| 329950-001 |
Six-Input Type B Sensor Interface Module |
4SITE Series 7943 Solid State Dispenser Pan and Containment Sensors |
| 330373-001 |
Six-Input Pressurized Line Leak Interface Module (One per console) |
Series 8484 Pressurized Line Leak Detection System Requires TLS-350 Plus Version 7.0 or higher software |
| 329356-004 |
8 Input Smart Sensor Module |
Requires Software 24.0 or higher software |
High-Power Compartment (Limit eight per console, unless otherwise noted)
| Form No. Factory Installed Modules |
Description |
Feature Compatibility |
| 329356-004 |
8 Input smart Sensor Module |
Requires ELS350 Version 24.0 or higher software |
| 329359-001 |
Four-Relay Output Interface Module |
|
| 329360-001 |
Two-Input/Two-Relay Output Interface Module |
|
| 329999-001 |
Pump Sense Interface Module |
Accepts Input from up to eight pump controls |
| 330374-001 |
Three-Output Pressurized Line Leak Controller Interface Module |
Series 8484 Pressurized Line Leak Detection System Requires TLS-350 Plus Version 7.0 or higher software |
Communications Compartment (Limit eight per console, unless otherwise noted)
| Form No. Factory Installed Modules |
Description |
Feature Compatibility |
| 330149-002 |
SiteFax Interface Module (Maximum three per console) |
Allows hookup to most remote facsimile, modem or teletype equipment. Requires TLS-350 Plus Version 3.0 or higher software |
| 330586-001 |
RS-485/232 Dual Port Communications Module (Maximum one per console) |
|
| 330148-001 |
RS-232 Interface Module with Auxiliary Port (Maximum one per console) |
Provides two 25-pin D-connectors for data transmission to P.O.S. terminal, printing device or computer |
| 329362-001 |
RS-232 Interface Module (Maximum three per console) |
Provides a 25-pin D-connector for data transmission to P.O.S. terminal, printing device, or computer |
| 330000-001 |
Remote Printer Interface Module (Maximum three per console) |
Provides a 25-pin D-connector for data transmission to a remote serial printer |
| 330883-001 |
WPLLD Communications Module (Maximum one per console) |
|
| 330020-425 |
Ethernet - TCP/IP Communications Module |
Requires Version 15.0 or higher software |
Temperature Range
Operating: 32ºF to 118ºF (0ºC to 45ºC)