TLS-350 Plus
UST Monitoring Systems
Veeder-Root's TLS-350 Plus takes business management a step beyond normal fuel inventory management. With its integrated, modular design, the TLS-350 Plus lets you choose the exact set of compliance and fuel management features you need today. As regulatory requirements change, the flexible TLS-350 Plus platform allows you to add new features tomorrow.
The TLS-350 Plus has defined the industry standard for tank monitoring systems with advanced magnetostrictive probe technologies offering 0.2 GPH monthly monitoring and 0.1 GPH volumetric tank testing; Continous Statistical Leak detection (CSLD) for 24-hour, automatic leak detection without tank shut down; accurate, automatic electronic line leak detection; 4SITE advanced technology sensors; and a complete line of standard leak sensors to monitor double-wall tanks, containment sumps, and wet and dry wells.
The SiteFax option provides auto-dial fax capability, letting you send up to 16 different reports to up to 8 separate fax machines on a programmable schedule and fax alarm messages instantaneously.
The optional fuel manager software available for the TLS-350 Plus allows you to track average daily fuel usage, predict the days of remaining inventory, and improve delivery scheduling.
By utilizing Inform, Veeder-Root's tank management software, all inventory management and environmental compliance can be easily centralized on a personal computer in one location.
Features
- Continuous inventory monitoring
- Fast 0.1 GPH in-tank leak detection for up to 12 tanks
- CSLD option for continuous 24-hour leak detection
- Electronic line leak detection capabilities
- SiteFax auto-dial fax capability
- 4SITE advanced technology sensor compatibility
- Interstitial and piping sump leak sensing for up to 64 sensors
- Vapor and groundwater monitoring for up to 40 wells
- External inputs
- Relay outputs
- Programmable alarms
- Data Communications
- Easy upgrade to BIR
- Emergency generator applications selectable via programming
- One system handles mix of standard and emergency generator tanks
- Records generator activity
- Complete inventory reports before and after generator operation
Standard Models
Console Form Number: 848290-022
Description: TLS-350 Plus Monitoring Console with integral printer (includes printer communications module)
Console Form Number: 848290-002
Description: TLS-350 Plus Monitoring Console without integral printer
Console Form Number: 848291-021
Description: TLS-350 Plus PC Version without Printer or Keyboard
TLS-350 Plus Interface ModulesThe TLS-350 Plus monitoring console contains three compartments in which individual interface modules can be installed. Interface modules may be factory-installed in the console upon initial ordering, or ordered separately as spare modules to expand an existing system.
Low-Power Compartment (Limit eight per console, unless otherwise noted)
| Form No. Factory Installed Modules |
Description |
Feature Compatibility |
| 329356-002 |
Four-Input Probe Interface Module (Maximum three per console. Includes terminal connector for one ground temperature thermistor for the volumetric line leak detector). |
Series 8463 Mag Plus Probe |
| 329358-001 |
Eight-Input Interstitial/Liquid Sensor |
Series 7943 Interstitial Sensor for Fiberglass Tanks and Interstitial Sensor for Steel Tanks Series 7943 Piping Sump Sensor Series 7943 Hydrostatic Sensor |
| 329357-001 |
Five-Input Vapor Sensor Interface Module |
Series 7943 Vapor Sensor |
| 329399-001 |
Five-Input Groundwater Sensor Module |
4SITE Series 7943 Groundwater Sensor |
| 329956-001 |
Eight-Input Type A Sensor Interface Module |
4SITE Series 7943 Solid State Discriminating Interstitial Sensor |
| 329950-001 |
Six-Input Type B Sensor Interface Module |
4SITE Series 7943 Solid State Dispenser Pan and Containment Sensors |
| 330373-001 |
Six-Input Pressurized Line Leak Interface Module (One per console) |
Series 8484 Pressurized Line Leak Detection System Requires TLS-350 Plus Version 7.0 or higher software |
High-Power Compartment (Limit eight per console, unless otherwise noted)
| Form No. Factory Installed Modules |
Description |
Feature Compatibility |
| 329359-001 |
Four-Relay Output Interface Module |
|
| 329360-001 |
Two-Input/Two-Relay Output Interface Module |
|
| 329999-001 |
Pump Sense Interface Module |
Accepts Input from up to eight pump controls |
| 330374-001 |
Three-Output Pressurized Line Leak Controller Interface Module |
Series 8484 Pressurized Line Leak Detection System Requires TLS-350 Plus Version 7.0 or higher software |
Communications Compartment (Limit eight per console, unless otherwise noted)
| Form No. Factory Installed Modules |
Description |
Feature Compatibility |
| 330149-001 |
SiteFax Interface Module (Maximum three per console) |
Allows hookup to most remote facsimile, modem or teletype equipment. Requires TLS-350 Plus Version 3.0 or higher software |
| 330586-001 |
RS-485/232 Dual Port Communications Module (Maximum one per console) |
|
| 330148-001 |
RS-232 Interface Module with Auxiliary Port (Maximum one per console) |
Provides two 25-pin D-connectors for data transmission to P.O.S. terminal, printing device or computer |
| 329362-001 |
RS-232 Interface Module (Maximum three per console) |
Provides a 25-pin D-connector for data transmission to P.O.S. terminal, printing device, or computer |
| 330000-001 |
Remote Printer Interface Module (Maximum three per console) |
Provides a 25-pin D-connector for data transmission to a remote serial printer |
| 330883-001 |
WPLLD Communications Module (Maximum one per console) |
|
Temperature Range
Operating: 32ºF to 118ºF (0ºC to 45ºC)
Storage: 15ºF to 118ºF (10ºC to 45ºC)