Veeder Logo

TLS-350J

UST Monitoring Systems

Veeder-Root's TLS-350J Monitoring System features in-tank leak detection, electronic line leak detection and discriminating sensing capability for up to 4 tanks/lines/sensors to meet regulatory compliance requirements at your site. The system comes equipped with Continuous Statistical Inventory Leak Detection (CSLD) which provides continuous 24-hour leak detection without tank shut down.

The TLS-350J comes equipped with standard or wireless electronic line leak detection for up to three lines. The risk management software will perform 0.1 GPH, 0.2 GPH and 3 GPH leak tests to meet EPA compliance requirements. Veeder-Root's electronic line leak detection is suitable for a variety of pipe types.

All systems support up to three Series 8473 Magnetostritive Probes. The Mag probes handle a wide variety of fuels and fluids and have been third party tested and certified to perform better than U.S. E.P.A. standards. Standard integral printer provides fast, quiet printouts.

The TLS-350J will accommodate three Veeder-Root float switch sensors including: interstitial sensors for both steel and fiberglass tanks, piping sump sensors, hydrostatic sensors and discriminating dispenser pan and containment sump sensors.

The TLS-350J systems are equipped with audible and visual alarms, triggered by in-tank and interstitial alarm condition. Any of the in-tank alarm limits can be tied to relays to trigger on-site devices, such as overfill alarms, or to shut down the submersibles.

Features

  • The total compliance solution for 2 and 4-tank/line systems
  • Built-in CSLD for continuous 24-hour leak detection
  • Supports PLLD and WPLLD for up to 4 lines
  • Supports up to three sensors for dispenser pan or containment sump sensing
  • Communication compartment has space available for three additional options; spaces can be filled with any standard TLS-350 communication board
  • High power compartment will accept up to 8 input/output modules
  • Built-in inputs provide for solid-state or switch input from external devices
  • Built-in outputs provide for overfill and external audible and visual warning devices.
  • Either relay can shut down the submersible if power to the monitor is lost or a leak is detected


Kit Form Number: 847095-322
Description:
TLS-350J console with integral printer, CSLD, PLLD risk management software, six input, three input PLLD line leak interfaces and three sensor input interfaces.

Kit Form Number: 847095-422
Description: TLS-350J console with integral printer, CSLD, WPLLD risk management software, six input, three input WPLLD line leak interfaces and three sensor input interfaces.

Kit Form Number: 847095-522
Description: TLS-350J 4-Tank/4 Sensor/4 PLLD Console with static in-tank leak detection and PLLD Risk Management Software with Integral Printer.

Kit Form Number: 847095-622
Description: TLS-350J 4-Tank/4 Sensor/4 WPLLD Console with static in-tank leak detection and WPLLD Risk Management Software with Integral Printer.

The following probes and sensors are compatible with the TLS-350J Monitoring System

Form No. Description
846390-XXX Mag Plus Probe
794390-40X Interstitial sensor for fiberglass tanks
794390-420 Interstitial sensor for steel tanks
794390-208 Piping sump sensor
794380-301 Single-float hydrostatic sensor
794380-302 Dual-float hydrostatic sensor
794380-322 Discriminating dispenser pan sensor
794380-352 Discriminating containment sump sensor

-
Product Brochures
 
» TLS-350J UST Monitoring System (576047-021 Rev A) (PDF)
Available in easy to order 2-, and 3-tank kits.

-
Related Links and Documents
 
» TLS-300/TLS-350/TLS-350R Quick Help (U.S.) (576013-939 Rev E) (PDF)
» TLS-3XX Consoles, Gilbarco EMC Series Consoles, ProPlus/ProMax Series Consoles Site Prep and Installation Manual (576013-879 Rev R) (PDF)
» TLS-3XX Series Consoles System Setup Manual (576013-623 Rev X) (PDF)
» TLS-3XX Series Consoles Troubleshooting Guide (576013-818 Rev P) (PDF)
» TLS-350 Series Board and Software Replacement (576013-637 Rev I) (PDF)
» Results of U.S. EPA Standard Evaluations Certification Reports - ATG Systems (576013-895 Rev G) (PDF)
Products: TLS Series 200, 200i, 300, 400, 8463, 8473, 8493, 8472
» TLS-300/TLS-350 Setup (Spanish) (576013-953-C) (PDF)
» TLS-XXX Operators (Spanish) (576013-954 Rev D) (PDF)
» TLS-300/TLS-350 Operators Manual (Spanish) (577013-775-A) (PDF)
» TLS-300/TLS-350/TLS-350R Quick Help (French) (577013-566 Rev B) (PDF)
» TLS-300/TLS-350/TLS-350R Quick Help (Italian) (577013-603 Rev B) (PDF)
» TLS-300/TLS-350/TLS-350R Quick Help (German) (577013-604 Rev C) (PDF)
» TLS-300/TLS-350/TLS-350R Quick Help (Russian) (577013-605 Rev B) (PDF)
» TLS-300/TLS-350/TLS-350R Quick Help (Greek) (577013-606 Rev B) (PDF)
» TLS-300/TLS-350/TLS-350R Quick Help (Polish) (577013-616 Rev B) (PDF)
» TLS-300/TLS-350/TLS-350R Quick Help (UK) (577013-617 Rev B) (PDF)
» TLS-300/TLS-350/TLS-350R Quick Help (Turkish) (577013-701 Rev A) (PDF)
» TLS-300/TLS-350/TLS-350R Quick Help (Dutch) (577013-704 Rev A) (PDF)
» TLS-300/TLS-350/TLS-350R Quick Help (Spanish) (577013-563 Rev B) (PDF)
» TLS-300/TLS-350/TLS-350R Quick Help (Chinese) (577013-725 Rev A) (PDF)
» TLS-300/TLS-350/TLS-350R Quick Help (Hebrew) (577013-726-A) (PDF)
» TLS-300/TLS-350/TLS-350R Quick Help (Danish) (577013-751 Rev A) (PDF)
» TLS-300/TLS-350/TLS-350R Quick Help (Swedish) (577013-792 Rev B) (PDF)
» TLS-300/TLS-350/TLS-350R Quick Help (Finnish) (577013-813 Rev A) (PDF)
   
Contact Us | Danaher Corp | Gilbarco | Gasboy | Privacy | Legal | Site Map
Copyright © 2007 The Veeder-Root Company All rights reserved. Unauthorized duplication prohibited.