Veeder Logo

Interstitial Sensor for Steel Tanks

Double Wall Tank Monitoring Our products offer the following features and benefits:

The Veeder-Root Interstitial Sensor for use in Steel Tanks detects the presence of liquid in the interstitial space of a double-wall steel tank. Liquid in the annulus could mean a dangerous leak. When liquid is detected, the sensor sends an alarm signal to a TLS-350R, TLS-350, TLS-350J, ILS-350, TLS-300i, or TLS-300C monitor. The monitor's visual and audible built-in alarm indicators immediately tell you where the problem is, so you can quickly take action to help prevent serious safety and environmental problems.

The TLS-350R, TLS-350, TLS-350J, ILS-350, TLS-300i, TLS-300C, TLS-250i, and ILS-250 systems feature internal alarm relays that can also trigger on-site alarms for even greater warning capability. The TLS-350R, TLS-350, TLS-300i, and TLS-300C alarm signals from the sensor triggers a report showing the time and the location of the alarm condition. This information is stored in the system's alarm history and can be retrieved through the monitor's integral printer or remotely through its data communications interface.

The Veeder-Root Interstitial Sensor for Steel Tanks can used in the annulus of steel tanks with a sensor riser pipe 1.5" I.D. or greater. Only two wires are required to connect the sensor to a TLS or ILS system.

Features

The presence of any liquid in the tank's interstitial space triggers a Fuel Alarm

Temperature Rating

Storage: -40 degrees C to + 75 degrees C
Operating: -20 degrees C to +70 degrees C (hydrocarbons); 0 degrees C to +70 degrees C (non-freezing water);

Cable length: 16 or 30 feet

Dimensions: 2.5" high, 1.50" diameter 

Standard Components

Quantity Description
1 Interstitial Steel Tank Sensor
2 Watertight Cord Grips

Standard Models

Form No. Description
794390-420 Interstitial Steel Tank Sensor with 16" cable
794390-460 Interstitial Steel Tank Sensor with 30" cable

Interstitial Steel Tank Sensor Console Capability

The Series 7943 Interstitial Steel Tank Sensor is compatible with the following consoles:
Console Series
TLS-350R* 8482
TLS-350* 8470
TLS-350J 8470
ILS-350** 8450
TLS-300i 8485
TLS-300C 8485
*Note: An Interstitial Sensor Interface Module is required for the use of the Interstitial Fiberglass Tank Sensor with the TLS-350 Console.
**Note: A Two-Wire Module is required for use of the Interstitial Fiberglass Tank Sensor with the ILS-350 Console.

-
Related Links and Documents
 
» Interstitial Liquid Sensor - Fiberglass Tanks - Installation Guide (576013-617 Rev F) (PDF)
» Point Sensor - Liquid Contact Product Detectors - Certification Reports - Results of U.S. E.P.A. Standard Evaluations (576013-864 Rev G) (PDF)
Products: TLS-350, TLS-300, TLS-300i, ILS-350, EMC, EMC BASIC, ProMax, ProPlus, Simplicity
» Liquid-Phase Product Detectors - Results of U.S. E.P.A. Standard Evaluations (576013-917 Rev. B) (PDF)
Products: 847990-001, 847990-002
» Sensor Products - Application Guide (577013-750 Rev M) (PDF)
» Solid-State Interstitial Liquid Sensor for Fiberglass Tanks - Installation Guide (576013-826 Rev H) (PDF)
» Interstitial Liquid Sensor - Steel Tanks Installation Guide (576013-616 Rev F) (PDF)
» Fiberglass Interstitial Sensor Installation Kit - User's Guide 577013-802 Rev B) (PDF)
   
Contact Us | Danaher Corp | Gilbarco | Gasboy | Privacy | Legal | Site Map
Copyright © 2009 The Veeder-Root Company All rights reserved. Unauthorized duplication prohibited.