Continuous Statistical Leak Detection Technology from Veeder-Root | Veeder-Root

Continuous Statistical Leak Detection

Continuous Statistical Leak Detection

Third-party testing that allows you to operate 24/7 and still meet all federal, state and local compliances. Continuous Statistical Leak Detection (CSLD) is certified leak-testing technology that continuously monitors fuel height and temperature to detect idle times in the tank. During each idle period, data is collected for a highly accurate leak-detection database. CSLD uses highly sophisticated statistical analysis to evaluate all information and discard invalid data. Tests are performed every time new data is collected.

Key features:

  • Works during idle periods, allowing continuous operation – no need to schedule test times
  • Compatible with TLS-450 and TLS-350 with leak detector cable probes
  • Continuous updates means results are always current and available at the press of a button
  • Test reports provided automatically every 24 hours
  • CSLD‘s algorithm sorts all available data and uses only highest-quality data to perform leak test, thereby reducing chances of false alarms

Key benefits:

  • Works during idle periods, allowing 24-hour, continuous operation – more uptime means more opportunity for site to generate revenue
  • Leak tests are performed using best data from up to 28 days – improves probability of receiving passing tests to satisfy federal, state and local compliance requirements
  • Test reports provided automatically every 24 hours – continual updates ensure early detection of any potential issues, thus reducing exposure to costly repairs
  • CSLD’s algorithm sorts all available data and uses only highest-quality data to perform leak test, thereby reducing chances of false alarms – 0% probability of false alarms gives users assurance of having a highly reliable leak detection system
  • Certified for Manifolded tanks – allows sites with high throughput potential to realize benefits of CSLDs continual data collection and analysis

Throughput Restrictions:

  • Idle time minimum - 6 to 10 hours
  • 221,890 gallon per month throughput limitation for CITLDS (only applicable in California)

CSLD may be installed in the following consoles:


Standard

Model

TLS-450

Series 8600

TLS-350 Plus

Series 8470

TLS-350R

Series 8482

TLS-300

Series 8485

In-Tank Probe Compatibility:

Probe Form Number: 846390-XXX

Product: MAG Plus Magnetostrictive Probe

Product: Magnetostrictive Probes for Alternative Fluids