Product Overview

Designed to provide the highest quality and most cost-effective tank monitoring system for cost-conscious retail petroleum marketers, the TLS-300i 3-4 Tank configurable console is an ideal value for many independent and/or smaller retail petroleum marketers.

Veeder-Root's TLS-300i Tank Monitoring System can be configured to provide in-tank leak detection or continuous statistical leak detection (CSLD) for underground storage tank (UST) applications with up to four Series 8463 Mag Plus Leak Detection Probes, or Series 8463 Mag Plus Inventory Probes to support Aboveground Storage Tank (AST) applications.

Additional configurable options are designed to provide printed documentation and remote monitoring flexibility. The optional Integral Printer provides fast, quiet continuos printouts. The optional SiteFax feature can be programmed to transmit leak detection and inventory reports, as well as real-time alarm reporting to fax machines or other communications devices.

Standard features include back-up generator capabilities, as well as capacity to accept up to eight Veeder-Root Series 7943 float-switch sensors. This high quality, low cost family of sensors includes interstitial leak sensors for steel and fiberglass tanks, piping sump sensors, hydrostatic sensors, and discriminating dispenser pan and containment sump sensors.

Specifications - Standard Features

  • System monitors up to four tanks.
  • RS-232 Communication Interface with Auxiliary Port provides two 25-pin D-connectors for data transmission to computers or point-of-sale terminals.
  • Automatic continuous leak sensing: tank interstitial space, piping sump
  • Audible alarm and display indicate leak location
  • In-tank warnings and alarms are activated for the following conditions: leak, overfill, low product, sudden loss, high water, delivery needed, test failure, tank test not performed.
  • Accepts up to eight interstitial / containment float switch sensors
  • Interstitial and piping sump warnings and alarms are activated for the following conditions: fuel presence, low liquid, high liquid
  • Alarm relays can trigger alarm/security devices
  • Two built-in inputs provide for solid-state or switch input from external devices
  • Two built-in output relays provide for outputs to overfill alarms and external audible and visual warning devices
  • Either relay can shut down the submersible if power to the monitor is lost or a leak is detected
  • Emergency generator applications are selectable via programming
  • One system handles a mix of standard and emergency generator tanks
  • Records generator activity
  • Complete inventory reports before and after generator operation

Configurable Options

  • Continuous Statistical Leak Detection for in-tank leak detection without tank shutdown.
  • Integral printer, which documents inventory leak detection, alarms and setup information.
  • SiteFax modem for remote management of leak detection and inventory alarms and reports.
  • One or two Veeder-Root Magnetostrictive Probes for 0.1 GPH in-tank leak detection with 4" float kit and 5" cable
  • One or two Veeder-Root Inventory Only Probes for Inventory Control with 4" float kit and 5" cable

Standard Models

Console Form No Description
848590-421 TLS-300i 3-4 Tank Configurable Console with Integral Printer
848590-411 TLS-300i 3-4 Tank Configurable Console without Integral Printer
848591-002 TLS-300i 3-4 Tank Configurable Console - PC Version
Software Enhancement Modules Note: Must be specified on order
330161-001 Static In-Tank Testing
330161-003 CSLD
Optional Site Fax Modem Note: Must be specified on order
331398-001 Site Fax Modem Kit for TLS-300 Series Consoles

The following probes and sensors are compatible with the TLS-300C Monitoring System:

Form No. Description
846390-XXX Mag Plus Inventory Measurement Probe
794390-40X Interstitial Sensor for Fiberglass Tanks
794390-420 Interstitial Sensor for Steel Tanks
794390-20X Piping Sump Sensor
794380-301 Single-Float Hydrostatic Sensor
794380-302 Dual-Float Hydrostatic Sensor
794380-322 Discriminating Dispenser Pan Sensor
794380-352 Discriminating Containment Sump Sensor

Please refer to Veeder-Root Price List for required probe and sensor lengths and corresponding 3-digit form number suffix.

-
Related Links and Documents
 
» TLS-300/TLS-350/TLS-350R Quick Help (U.S.) (576013-939 Rev F) (PDF)
» TLS-3XX Consoles, Gilbarco EMC Series Consoles, ProPlus/ProMax Series Consoles Site Prep and Installation Manual (576013-879 Rev R) (PDF)
» TLS-3XX Series Consoles System Setup Manual (576013-623 Rev Y) (PDF)
» TLS-3XX Series Consoles Troubleshooting Guide (576013-818 Rev Q) (PDF)
» Results of U.S. EPA Standard Evaluations Certification Reports - ATG Systems (576013-895 Rev G) (PDF)
Products: TLS Series 200, 200i, 300, 400, 8463, 8473, 8493, 8472
   
Contact Us | Danaher Corp | Gilbarco | Gasboy | Privacy | Legal | Site Map
Copyright © 2009 The Veeder-Root Company All rights reserved. Unauthorized duplication prohibited.